Dell 2T227 Power Supply User Manual


 
Dell PowerConnect RPS-600 Setup Guide 11
Mounting Instructions
NOTICE: Before you install the PowerConnect™ RPS-600, consult your
PowerConnect switch User's Guide to confirm that your switch supports the
PowerConnect RPS-600 Redundant Power Bank.
Installing the PowerConnect RPS-600 on a Flat Surface
You can install the RPS-600 on any appropriate level surface that can safely
support the weight of the switches, the RPS-600, and their attached cables.
There must be adequate space around the RPS-600 for ventilation and to
access cable connectors.
To install the RPS-600 on a flat surface:
1 Set the RPS-600 on the flat surface and check for proper ventilation.
NOTICE: Allow at least 2 inches (5.1 cm) on each side for proper ventilation
and 5 inches (12.7 cm) at the back for power-cord clearance.
2
Attach rubber feet on each marked location on the bottom of
the chassis.
The rubber feet are optional, but recommended to keep the unit
from slipping.
Installing the PowerConnect RPS-600 in a Rack
The RPS-600 can be installed in most standard 19-inch racks.
NOTE: For racks that are not prethreaded, cage nuts are provided.
To install the RPS-600 in a rack:
1 Use the supplied screws to attach a mounting bracket to each side of
the RPS-600.
2 Position the RPS-600 in the rack and align the holes in the mounting
bracket with the holes in the rack.
3 Insert and tighten two screws appropriate for your rack through each of
the mounting brackets.