Dell R200 Server User Manual


 
20 About Your System
NOTE: If you receive a system message that is not listed in Table 1-4, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
CAUTION: Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.
Table 1-4. System Messages
Message Causes Corrective Actions
Attempting to
update Remote
Configuration.
Please wait....
Remote Configuration is in
progress.
Wait until the process is
complete.
BIOS Update Attempt
Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update. If
the problem persists, see
"Getting Help" on
page 127.
Caution! NVRAM_CLR
jumper is installed
on system board.
NVRAM_CLR jumper is
installed.
Check the System Setup
configuration settings. See
"Using the System Setup
Program
" on page 35.
Remove the NVRAM_CLR
jumper. See Figure 6-1 for
jumper locations.
Data error The diskette drive or hard
drive cannot read the data.
For the operating system,
run the appropriate utility
to check the file structure
of the diskette drive or hard
drive.
See your operating system
documentation for
information on running
these utilities.
book.book Page 20 Thursday, August 30, 2007 3:30 PM