Dell R805 Computer Hardware User Manual


 
on a component that resides in the specified slot.
If the problem persists, the riser card or system board is faulty. See Getting
Help.
E1714
Unknown Err
The system BIOS has determined that there has
been an error in the system, but is unable to
determine its origin.
See Getting Help.
E171F
PCIE Fatal Err
B## D## F##
The system BIOS has reported a PCIe fatal error
on a component that resides in PCIe configuration
space at bus ##, device ##, function ##.
Remove and reseat the PCIe expansion cards. If the problem persists, see
Troubleshooting Expansion Cards.
PCIE Fatal Err
Slot #
The system BIOS has reported a PCIe fatal error
on a component that resides in the specified slot.
Reinstall the expansion-card riser. See Expansion-Card Risers.
If the problem persists, the riser card or system board is faulty. See Getting
Help.
E1810
HDD ## Fault
The SAS subsystem has determined that hard
drive ## has experienced a fault.
See Troubleshooting a Hard Drive.
E1811
HDD ## Rbld Abrt
The specified hard drive has experienced a rebuild
abort.
See Troubleshooting a Hard Drive. If the problem persists, see your RAID
documentation.
E1812
HDD ## Removed
The specified hard drive has been removed from
the system.
Information only.
E1914
DRAC5 Conn2 Cbl
DRAC 5 cable is missing or disconnected.
Reconnect the cable. See Installing a RAC Card.
E1915
IO55 HTSink
Missing
MCP55 Htsink
Missing
Heatsink sensor reports that the chipset IO55
heatsink is missing.
Heatsink sensor reports that the chipset MCP
heatsink heatsink is missing.
See Getting Help.
E1A12
PCI Rsr Missing
One or all of the PCIe risers is missing, preventing
the system from powering on.
Reinstall the missing riser card(s).
E1A14
SAS Cable A
SAS cable A is missing or bad.
Reseat the cable. If the problem persists, replace cable. See SAS Controller
Daughter Card.
E1A15
SAS Cable B
SAS cable B is missing or bad.
Reseat the cable. If the problem persists, replace cable. See SAS Controller
Daughter Card.
E1A1C
LOM Mezz Missing
LOM daughter card is missing.
Install or reseat the LOM daughter card. If the problem persists, replace the
card. See Getting Help.
E1B01
USB# Overcurrent
Device plugged in the specified USB port caused
an overcurrent condition.
Reseat the device cable. If the problem persists, replace or remove the
device.
E2010
No Memory
No memory is installed in the system.
Install memory. See Installing Memory Modules.
E2011
Mem Config Err
Memory detected, but is not configurable. Error
detected during memory configuration.
See Troubleshooting System Memory.
E2012
Unusable Memory
Memory is configured, but not usable. Memory
subsystem failure.
See Troubleshooting System Memory.
E2013
Shadow BIOS Fail
The system BIOS failed to copy its flash image into
memory.
See Troubleshooting System Memory.
E2014
CMOS Fail
CMOS failure. CMOS RAM not functioning properly.
See Getting Help.
E2015
DMA Controller
DMA controller failure.
See Getting Help.
E2016
Int Controller
Interrupt controller failure.
See Getting Help.
E2017
Timer Fail
Timer refresh failure.
See Getting Help.
E2018
Prog Timer
Programmable interval timer error.
See Getting Help.
E2019
Parity Error
Parity error.
See Getting Help.
E201A
SIO Err
SIO failure.
See Getting Help.
E201B
Kybd Controller
Keyboard controller failure.
See Getting Help.
E201C
SMI Init
System management interrupt (SMI) initialization
failure.
See Getting Help.
E201D
Shutdown Test
BIOS shutdown test failure.
See Getting Help.
E201E
POST Mem Test
BIOS POST memory test failure.
See Troubleshooting System Memory. If problem persists, see Getting Help.
E201F
DRAC Config
Dell remote access controller (DRAC) configuration
failure.
Check screen for specific error messages.
Ensure that DRAC cables and connectors are properly seated. If problem
persists, see your DRAC documentation.
E2020
CPU Config
CPU configuration failure.
Check screen for specific error messages.
E2021
Memory Population
Incorrect memory configuration. Memory
population order incorrect.
Check screen for specific error messages. See Troubleshooting System
Memory.
E2022
POST Fail
General failure after video.
Check screen for specific error messages.
E2110
MBE DIMM # & #
One of the DIMMs in the set implicated by "# & #"
has had a memory multi-bit error (MBE).
See Troubleshooting System Memory.
E2111
SBE Log Disable
DIMM #
The system BIOS has disabled memory single-bit
error (SBE) logging, and will not resume logging
further SBEs until the system is rebooted. "#"
represents the DIMM implicated by the BIOS.
See Troubleshooting System Memory.
E2112
Mem Spare DIMM #
The system BIOS has spared the memory because
it has determined that the memory had too many
errors. "# & #" represents the DIMM pair
implicated by the BIOS.
See Troubleshooting System Memory.