Delta Electronics DVPDT02-H2 Network Card User Manual


 
DeviceNet Slave Communication Module DVPDT02-H2
DVP-PLC Application Manual
3
1 Introduction
1. To ensure correct installation and proper operation of DVPDT02-H2, please read this chapter carefully
before using your DVPDT02-H2.
2. This chapter only provides introductory information on DVPDT02-H2. Details of DeviceNet protocol are not
included. For more information on DeviceNet protocol, please refer to relevant reference or literatures.
3. DVPDT02-H2 is a DeviceNet slave communication module, used for the connection between DeviceNet
network and DVP-EH2 series PLC MPU.
1.1 Features
z Supports Group 2 only servers.
z Supports explicit connection in the pre-defined master/slave connection group.
z Supports polling.
z Supports EDS files in DeviceNet network configuration tools.
z The length of I/O data can be freely configured through DeviceNet network configuration tool. Re-power
it to make effect the configuration.
z I/O data is extendable to 200 bytes.
1.2 Specifications
DeviceNet connection
Transmission method CAN
Electrical isolation 500VDC
Interface Removable connector (5.08mm)
Transmission cable 2 communication cables, 2 power cables, 1 shielded cable
Communication
Message type I/O polling; explicit
Serial transmission
speed
125 kbps; 250 kbps; 500 kbps (bits per second)
Electrical specification
Voltage 24VDC (Range: 11 ~ 25VDC)
Current 28mA (typical), 125mA impulse current (24VDC)
Environment
Noise immunity
ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV
Analog & Communication I/O: 1KV
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
Operation 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2
Storage -25ºC ~ 70ºC (temperature); 5 ~ 95% (humidity)
Vibration/shock
resistance
Standard: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27
(TEST Ea)
Certificates IEC 61131-2, UL508