EMC FC5700 Network Hardware User Manual


 
5
Cable and Configuration Guidelines
5-23
Storage System Hardware
Table 5-4 Cable Sizes Copper
Component planning diagrams and worksheets follow.
Length Typical Use
0.3 m (1 ft), non-equalized Connecting DPE/DAE and DAE LCCs
1.0 m (3.3 ft), non-equalized Connecting a hub to an adjacent storage system
3 m (10 ft), non-equalized Connecting a hub to a storage system in the same cabinet, or daisy
chaining from one cabinet to an adjacent cabinet
5 m (16.5 ft), non-equalized Connecting a hub in one rack to a storage system in another cabinet
10 (33 ft), non-equalized Connecting servers to hubs and/or storage systems maximum
length for non-equalized copper cable, maximum length between LCCs
30 m (98.5 ft), equalized Connecting servers to hubs and/or storage systems maximum length
for copper cable
Copper cabling is shielded, 75-ohm twin-axial, shield bonded to DB-9 plug connector shell (360
o
) FC-AL
Standard, Revision 4.4 or higher.