Note the following points at the time of installing RTM-ATCA-7350:
z Make sure that you wear an electrostatic discharge (ESD)-preventive wrist strap to prevent
the static electricity from hurting you or damaging the device.
z Keep your personal objects such as your clothes away from RTM-ATCA-7350. To prevent
the static electricity on clothing, you need to put on antistatic clothing.
z RTM-ATCA-7350 is installed in the slot paired with the server blade slot at the back side of
the shelf. RTM-ATCA-7350 is powered from the payload power of the front board. You
should install RTM-ATCA-7350 before payload power of the front board is turned on. Hot
swap of the RTM-ATCA-7350 while under power is not supported.
z Hold the ejector handles and the face plate when you insert or remove RTM-ATCA-7350.
Do not touch the components inside of the blades.
z Keep the blade vertical when you install RTM-ATCA-7350. Align the blade with the slot and
then insert it in the shelf.
2.4.1 Ejector Handles
RTM-ATCA-7350 is powered by the server blade in the slot paired with the RTM-ATCA-7350
slot. RTM-ATCA-7350 does not support hot swap. As shown in Figure 1-4, the face plate of
RTM-ATCA-7350 provides an upper and a lower ejector handles. The ejector handles help to
insert, remove, fasten, power on, and power off RTM-ATCA-7350.
2.4.2 ESD Prevention
Static electricity may hurt you or damage the device. To minimize the damage, pay attention to
the following points:
z Before you operate the device, wear the ESD-preventive wrist strap. Both terminals of the
ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and the
other is inserted in the jack at the front or back side of the shelf. For details on how to wear
the ESD-preventive wrist strap, refer Wearing the ESD-Preventive Wrist Strap on page 21.
z Avoid moving your body as much as possible. Movement gathers static electricity around
you.
z Do not touch the solder point, pin, or bare circuit.
z Do not leave the device in the place where others can operate it.
Module Damage
If the blade is not fully aligned with the interface in the backplane, too much force may
twist the pins on the blade or backplane.
Do not exert too much force when you insert the blade.