8.5 Demo Configuration to the Enfora Test Server
The Mini-MT is capable of communicating with a server. The following steps will guide
you through a configuration that will demonstrate the data communication capabilities to
the Enfora Test Server. A valid SIM card from your carrier is required that allows GPRS
data communications capability.
8.5.1 Reset the modem to factory defaults
To restore the Mini-MT to factory defaults send the following command:
AT&F<CR>
To save the current configuration to memory send the following command:
AT&W<CR>
Reset the modem with the following command:
AT$RESET<CR>
8.5.2 Connecting the Mini-MT to the Enfora Test Server
The following information will be required from the SIM card provider (refer to
GSM0000AN019 – Network Configuration Worksheet):
• APN
• Username (if required)
• Password (if required)
• SIM PIN (if required)
The following examples show how to configure the Mini-MT with a Cingular SIM card
with the following data:
• APN=isp.cingular
• Username=ISP@CINGULARGPRS.COM
• Password=CINGULAR1
• SIM PIN=1234
GSM2228UG001 Page 31