Overview of DFE-Platinum Module Shutdown Procedure
4-6 Troubleshooting
Recommended Shutdown Procedure
BeforepullingaDFEPlatinummoduleoutofachassis,
pressortaponits
OFFLINE/RESETswitchforlessthan1 second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicatingthatthe
moduleisshuttingdown.Attheendoftheshutdownroutine,theCPULEDchangestoa67%/
33%sequenceofamber/off,respectively,indicatingthemoduleisinahalt
state.Inthistimeitis
safetorestartorremovethemodule fromthechassis.
Whenacontrolledshutdownisinitiatedfromthe
OFFLINE/RESETswitch,youhave60seconds
fromthetimetheCPUstartsalternatelyflashingamber/offuntilthedeviceautomaticallyrestarts.
Last Resort Shutdown Procedure
ToresetaDFEPlatinummodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe
OFFLINE/RESETswitchforapproximately6seconds.
PullinganyDFEPlatinummoduleoutofthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetopullamoduleoutofthechassisisafterthecompletionofa
shutdownandthemanagementLEDisalternatelyflashingamber/off.
Caution: Do not remove a DFE module from an operating chassis system before reading the
following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las siguientes
instrucciones y la información suministrada.
Note: The only safe time to pull a DFE-Platinum module out of the chassis is when the CPU LED is
alternately flashing amber/off. Otherwise, system operation will be interrupted.
Caution: This method of shutting down a DFE module is not recommended except as a last resort,
because all processes currently running on the module will be interrupted resulting in loss of
frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE. Recurra a él
sólo como último recurso, puesto que interrumpe todos los procesos del módulo en
funcionamiento, lo que podría resultar pérdidas de frames.