Enterasys Networks 700 Switch User Manual


 
Alarm Configuration
4-8 Basic Alarm Configuration
7. In the Rising Action field, click to select the action you want your device to
take in response to a rising alarm: Enable Port, Disable Port, or None. Note
that this action enables or disables only
bridging
at the specified port, and not
the interface itself.
For more information on how actions are triggered, see How Rising and
Falling Thresholds Work, on page 4-27.
8. Click in the Falling Threshold field, and enter the low threshold value for this
alarm. Remember, compared values are always relative, or delta values (the
difference between the value counted at the end of the current interval and
the value counted at the end of the previous interval); be sure to set your
thresholds accordingly.
When configuring a Kilobits alarm, NetSight Element Manager converts
octets into kilobits (units of 125 bytes, or octets) for you; for example, to set a
falling threshold of 625 octets, enter a threshold value of 5.
9. In the Falling Action field, click to select the action you want your device to
take in response to a falling alarm: Enable Port, Disable Port, or None. Note
that this action enables and disables only
bridging
at the specified port, and
not the interface itself.
For more information on how actions are triggered, see How Rising and
Falling Thresholds Work, page 4-27.
10. Click the Apply button to set your changes. If you have made any errors in
configuring alarm parameters (using an invalid rising or falling threshold, for
example, or neglecting to supply a polling interval), either an error window
with the appropriate message will appear, or a beep will sound and the cursor
will blink in the field which contains the error. Correct the noted problem(s),
and click Apply again.
Once you click the Apply button, the configured alarm parameters will be set for
every selected interface, and the alarms will automatically be enabled; the list box
display will also refresh to reflect these changes.
To configure additional alarms, or alarms of a different type, select the
appropriate alarm variable at the top of the window, highlight the appropriate
interface(s), and repeat the procedures outlined above.
TIP
The Actions fields will be grayed out for devices that do not support the proprietary
Actions MIB.