DFE-Gold Module Shutdown Procedure
Matrix DFE-Gold Series Installation Guide 4-7
YoucanshutdownaDFEGoldmoduleinanoperatingsystemusingthe
OFFLINE/RESET
switchshowninFigure 42.Therearetwoprocedurestoshutdowna
DFEGoldmodule.
“RecommendedShutdownProcedureUsingOFFLINE/RESETSwitch”(page 47)
“LastResortShutdownProcedureUsingOFFLINE/RESETSwitch”(page 48)
Figure 4-2 OFFLINE/RESET Switch
Recommended Shutdown Procedure Using OFFLINE/RESET
Switch
BeforepullingaDFEGoldmoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1 second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicating
thatthemoduleisshuttingdown.Attheendoftheshutdownroutine,theCPULED
changestoa67%/33%sequenceofamber/off,respectively,indicatingthemoduleisina
haltstate.Inthistimeitissafetorestartorremovethemodulefromthechassis.
1 OFFLINE/RESET switch (in similar location on all DFE modules)
COM
OFFLINE/
RESET
GROUP 3
GROUP 1 GROUP 2
CPU
MGMT
1X
6X
4G4202-72
Gb ENET
À
Caution: Do not remove a DFE module from an operating chassis system before reading
the following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las
siguientes instrucciones y la información suministrada.