Enterasys Networks A2H123-24 Switch User Manual


 
Troubleshooting Checklist
SecureStack A2 Installation Guide 4-7
Cannot contact the
SecureStack A2
through in-band
management.
IP address not assigned. Refer to the SecureStack A2
Configuration Guide for the IP address
assignment procedure.
Port is disabled. This is normal if the switch is a Member in
a stack.
If operating as a standalone switch or as
the Manager in a stack, enable the port.
Refer to the SecureStack A2
Configuration Guide for instructions to
enable/disable ports.
No link to switch. Verify that all network connections
between the network management station
and the device are valid and operating.
If the problem continues, contact
Enterasys Networks for technical support.
Port(s) goes into
standby for no
apparent reason.
Loop condition detected. Verify that Spanning Tree is enabled.
Refer to the SecureStack A2
Configuration Guide for the instructions to
set the type of STA.
Review the network design and delete
unnecessary loops.
If the problem continues, contact
Enterasys Networks for technical support.
User parameters (IP
address, switch and
module name, etc.)
were lost when the
SecureStack A2
power was cycled.
Clear NVRAM was set using
CLI commands.
Reenter the lost parameters as
necessary. Refer to the SecureStack A2
Configuration Guide for the instructions to
configure the SecureStack A2 using CLI
commands.
If the problem continues, contact
Enterasys Networks for technical support.
Table 4-2 Troubleshooting Checklist (continued)
Problem Possible Cause Recommended Action