Enterasys Networks 7G4285-49 Switch User Manual


 
Using LANVIEW
DFE-Platinum Series Hardware Installation Guide 4-5
Table 4-1 LANVIEW LEDs
LED Color State Recommended Action
MGMT Off Off. This DFE module is NOT
the Management Module.
None.
Green Solid. This module is the
designated Management
Module.
None.
Amber Flashing. This is a
temporary indication that the
DFE module is saving data.
None.
CPU Off Power off. Ensure chassis has adequate power.
Amber Blinking. DFE module in
process of booting.
None.
Solid. Testing. If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green Blinking. Image starts
running.
None.
Solid. Functional. None.
Red Solid. Processor in reset. None.
Green and
Amber
Blinking. Indicates that the
DFE module is in the process
of shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE module.
Amber and
off
Alternating (67% on, 33%
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
While in this state, you have 60
seconds to safely remove the DFE
module from the chassis.