Enterasys Networks B2G124-24 Switch User Manual


 
Troubleshooting Checklist
Enterasys SecureStack B2 Installation Guide 4-7
Cannot navigate
beyond startup
screen.
Improper Community Names
Tab le .
Refer to the SecureStack B2 Configuration Guide for the
Community Names Table setup.
Cannot contact the
switch through in-
band management.
IP address not assigned. Refer to the SecureStack B2 Configuration Guide for the IP
address assignment procedure.
Port is disabled. This is normal if the switch is a Member in a stack.
If operating as a standalone switch or as the Manager in a
stack, enable the port. Refer to the SecureStack B2
Configuration Guide for instructions to enable/disable ports.
No link to switch. Verify that all network connections between the network
management station and the device are valid and operating.
If the problem continues, contact Enterasys Networks for
technical support.
Port(s) goes into
standby for no
apparent reason.
Loop condition detected. Verify that Spanning Tree is enabled. Refer to the
SecureStack B2 Configuration Guide for the instructions to
set the type of STA.
Review the network design and delete unnecessary loops.
If the problem continues, contact Enterasys Networks for
technical support.
User parameters (IP
address, switch and
module name, etc.)
were lost when the
switch power was
cycled.
Clear NVRAM was set using
CLI commands.
Reenter the lost parameters as necessary. Refer to the
SecureStack B2 Configuration Guide for the instructions to
configure the switch using CLI commands.
If the problem continues, contact Enterasys Networks for
technical support.
Table 4-2 Troubleshooting Checklist (continued)
Problem Possible Cause Recommended Action