Enterasys Networks RBT-1002C Network Router User Manual


 
C
OMPLIANCES
XIX
Safety Compliance
Power Cord Safety
Please read the following safety information carefully before installing the
access point:
WARNING: Installation and removal of the unit must be carried out by qualified
personnel only.
The unit must be connected to an earthed (grounded) outlet to comply with in-
ternational safety standards.
Do not connect the unit to an A.C. outlet (power supply) without an earth
(ground) connection.
The appliance coupler (the connector to the unit and not the wall plug) must have
a configuration for mating with an EN 60320/IEC 320 appliance inlet.
The socket outlet must be near to the unit and easily accessible. You can only
remove power from the unit by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions according
to IEC 60950. The conditions are only maintained if the equipment to which it is
connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
supplies. If your supplies are of IT type, this
unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with
the secondary connection point labelled Neutral, connected directly to earth
(ground).
Impédance à la terre
Important! Before making connections, make sure you have the correct cord set.
Check it (read the label on the cable) against the following:
Power Cord Set
U.S.A. and Canada The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least
10 A
The attachment plug must be an earth-grounding type with
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
Denmark The supply plug must comply with Section 107-2-D1, Stan-
dard DK2-1a or DK2-5a.