Epson M4X11 Printer User Manual


 
1.2.5 Electrical Specifications
Table 1-8. Rated Electrical Ranges
Specification
120 V Version 220 - 240 V Version
Rated voltage
120 VAC 220 - 240 VAC
Input voltage range
103.5
132 V
198
264 V
Rated frequency range
50
60 Hz
50
60 Hz
Input frequency range
49.5
60.5 Hz
49.5
60.5 Hz
Rated current
0.5 A 0.3 A
Power consumption
Approx. 15 W
(self-test with 10-cpi LQ characters)
Approx. 15 W
(self-test with 10-cpi LQ characters)
Insulation resistance
10 MΩ,
minimum
(applying 500 VDC between AC
line and chassis)
10 M
, minimum
(applying 500 VDC between AC line
and chassis)
Dielectric strength
1000 VAC rms for 1 minute or
1200 VAC rms for 1 second
(between AC line and chassis)
1500 VAC rms for 1 minute
(between AC line and chassis)
1.2.6 Environmental Conditions
Table 1-9. Acceptable Environmental Conditions
Condition
Operating Non Operating
Temperature
10
35
°
C (50
95
°
F)
*1
20
60
°
C (
4
122
°
F)
*2
Humidity
20
80% RH
*1, 3
5
85% RH
*2, 3
Shock resistance
1G (within 1 msec.) 2G (within 2 msec.)
*2
Vibration resistance
0.15 G 0.50 G
*2
*1 : For printer operation, conditions must be in the range shown in the figure below.
*2
: These conditions are applicable when the printer is in its shipping container.
*3
: Without condensation.
80%
55%
20%
Humidity
(% RH)
Guaranteed Range
(Degrees)
10 27 35
Figure 1-5. Temperature/Humidity of Range
Epson Stylus Color 200 /Epson Stylus 200 Product Description
Rev. A 1-7