This command is enabled only when no data exists in the print buffer. When data
exists in the print buffer, the printer processes the data following
m
as normal data.
After printing the bar code, this command sets the print position to the beginning of the
line.
This command is not affected by print modes.
The number of data for the ITF bar code must be even numbers. When an odd
number of bytes of data is input, the printer ignores the last received data.
When Code128 (m=49h) is used:
1. Refer to
APPENDIX E – CODE 128 BAR CODE
for the information for the
Code128 bar code and its code table.
2. When using Code128 in this printer, take the following points into account for data
transmission:
#
The top of the bar code data string must be the code set
selection character (CODE A, CODE B or CODE C),
which selects the first code set.
#
Special characters are defined by combining two
characters “
{
“ and one character. The ASCII character “
{
is defined by transmitting “
{
“ twice consecutively.
Transmit data
Specific character
ASCII Hex Decimal
SHIFT {S 7B, 53 123, 83
CODE A {A 7B, 41 123, 65
CODE B {B 7B, 42 123, 66
CODE C {C 7B, 43 123,67
FNC1 {1 7B, 31 123, 49
FNC2 {2 7B,32 123, 50
FNC3 {3 7B, 33 123,51
FNC4 {4 7B,34 123, 52
“{“ {{ 7B, 7B 123, 123
[Example] Example data for printing “Ref. 258710”
In this example, the printer first prints “No.” Using CODE B, then prints the
following numbers using CODE C.
GS k
73 11 123 66 82 101 102 46 123 67 25 87 10
3. If the top of the bar code data is not the code set selection character, the printer stops
command processing and processes the following data as normal data.
4. If the combination of “{“ and the following character does not apply any special
character, the printer stops command processing and processes the following data as
normal data.
5. If the printer receives characters that cannot be used in the special code set, the
printer stops command processing and processes the following data as normal data.
6. The printer does not print HRI characters that correspond to the shift characters or
code set selection characters.
7. HRI character for the function character is space.
8. HRI characters for the control character (<00>H to <1F>H and <7F>H) are space.
<Others> Be sure to keep spaces on both right and left sides of a bar code. (Spaces are different
depending on the types of the bar code.)
[Reference]
GS h
,
GS w
Fig. 4.1-
Code128
code example.