19
Monitoring window layout
*1 When "Temperature level display group view" is set to "On" at
"Environment setup" in the "Tool" menu, an icon indicating the internal
temperature of the projector will be displayed on top of the projector
icon. The default setting is "Off".
*2 Check the following items.
Check that the projector's power is turned on.
Check that the LAN cable is connected.
Check that "Network Monitoring" is set to "ON" or "Standby Mode"
is set to "Network ON" in the projector's configuration menu.
*3 Check that the projector has been correctly connected to the network.
*4 You can display the lamp life warning at any time preset at
"Environment setup" in the "Tool" menu.
f Selecting display items
You can select only the required items to be displayed in "Detail list view".
PROCEDURE
Select "Option" from the "View" menu.
The "Option" window will be displayed.
Select the check box of the item you want to display.
Click [OK].
Error information: Shows the warning or problem status using the
following icons.
Lamp life warning
*4
Lamp out
High-temperature
warning
Lamp failure at
power on
Replace Air Filter
High internal
temperature error
No Air Filter
Internal (system)
error
Low Air Flow Fan error
Air Flow Sensor Err. Sensor error
Open lamp cover
door error (lamp
error)
Other error
TIP
The projector information that is generated when a problem is
detected is stored until EMP Monitor is closed. The EMP Monitor
displays will not be updated automatically even if the projector status
returns to normal. Click [Refresh] in the main window to update the
status.
1
2
3