PS 124 12 VDC, 4 Amp Power Supply • Installation Manual
1
Introduction
TheExtronPS124isahighperformance,plenumrated(with
optionalFlexibleConduitkit),12VDCpowersupply.The
autoswitchable100VACto240VACinputcansupplya
maximumcurrentof4ampsforuptoeightoutputs. Each
DCoutputisonatwo-polecaptivescrewconnector,withno
per-outputcurrentlimitation.Two-toneLEDsonthefrontand
rear panels indicate normal operation (green) and overload
condition (red).
TherackmountablePS124hasa1Uhigh,quarterrackwide,
9"deepmetalenclosure,allowingthePS124totakeadvantage
of a variety of mounting options.
Front and Rear Panel Features
All power and output connections are on the rear panel.
RED-OVERLOAD
P/S 124
12 VDC 4A POWER SUPPLY
OUTPUTS
RED-
OVERLOAD
100-240 50-60Hz 1.2A MAX.
OUTPUTS
RED-
OVERLOAD
100-240 50-60Hz 1.2A MAX.
12 V TOTAL OUTPUT 4A
12 V TOTAL OUTPUT 4A
D E FCC
Figure 1 — PS 124 front and rear panels
LED indicators
a
Power status LEDs—ThesefrontandrearpanelLEDsindicate
thePS124statusbylightingasfollows:
• Green when power is applied and current draw is normal
• Red indicates a current overload condition
C
Continued operation in an overload condition may
cause premature power supply failure.
• Unlit when an output is shorted
N
To identify the shorted output, unplug the outputs one at
a time until the LEDs light green.