Alarm Type Description - Encoder
Alarm Type Description Action Default Settings
Encoder Alarm
No source No source present at the input. Check input connections;
is there an output on the
loop through connector?
Critical, reporting
Bad source syncs Source is present, but
unrecognized ue to bad sync mea-
surement.
Critical, reporting
No SDI source lock Applicable to VN 300, ignore for
VN 200.
Critical, reporting
Unsupported SDI
mode
Applicable to VN 300, ignore for
VN 200.
Critical, reporting
Unsupported mode Source is present, mode not
supported.
Critical, reporting
Bad source Critical, reporting
Analog phasing
error
Warning, reporting
Hardware encoding
error
The hardware is unable to encode
the input signal.
Critical, reporting
Unsupported audio
source
Critical, reporting
Data rate overload The compressed data rate is too
high.
Increase the compression
or reduce the required bit
rate
Critical, reporting
Network overload The network is dropping too many
packets.
Warning, reporting
VN-Matrix 200 Series • Alarms and SNMP 89