Transfer Temperature
Command Line Usage CUPS option Description
TransferHeat =0
<150 to 190>
Transfer Heat = 0
<150 to 190>
Transfer Temperature Sets
temperature for InTM transfer in
Celsius Lower
limit = 150.0 Celsius, Upper limit =
190.0 Celsius
• UltraCard III - Composite: Default
= 175.0 Celsius
• UltraCard- PVC: Default = 175.0
Celsius
• Custom: Default = 175.0 Celsius
Transfer Dwell Time
Command Line Usage CUPS option Description
TransferDwell =20
<10 to 30>
Transfer Dwell = 20
<1.0 to 3.0>
Transfer Dwell Time Sets dwell time
for InTM transfer in seconds per
inch
Lower limit = 1.0 seconds per inch,
Upper limit = 3.0 seconds per inch
• UltraCard III - Composite: Default
= 2.0 seconds per inch
• UltraCard - PVC: Default = 2.0
seconds per inch
• Custom: Default = 2.0 seconds
per inch
HDP5000 Cups (Linux & MAC OS) User Guide Rev1.1
18