Fortinet FortiLog-100 Network Card User Manual


 
Setting up the FortiLog unit Planning the installation
FortiLog Administration Guide 05-16000-0082-20050115 17
Power requirements
FortiLog-100
AC input voltage: 100 to 240 VAC
AC input current: 1.0 A
Frequency: 47 to 63 Hz
FortiLog-400 and 800
AC input voltage: 115 to 230 VAC
AC input current: 4 to 2 A
Frequency: 47 to 63 Hz
Environmental specifications
Operating temperature: 41 to 95°F (5 to 35°C)
If you install the FortiLog unit in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient temperature. Therefore, make sure to install the equipment in an
environment
compatible with the manufacturer's maximum rated ambient temperature.
Storage temperature: -4 to 176°F (-20 to 80°C)
Humidity: 10 to 90% non-condensing
Air flow
For rack installation, make sure that the amount of air flow required for safe
operation of the equipment is not compromised.
For free-standing installation, make sure that the appliance has at least 1.5 in.
(3.75 cm) of clearance on each side to allow for adequate air flow and cooling.
Mechanical loading
For rack installation, ensure an even mechanical loading of the FortiLog unit to avoid a
hazardous condition.
Planning the installation
You can add the FortiLog unit to your local network to receive log messages from your
local FortiGate and FortiMail devices or act as a NAS server.
You can also connect the FortiLog unit to devices remotely through the Internet.
To connect the FortiLog unit to devices remotely, you must configure the DNS server
and the default gateway.
To manage the FortiLog unit, you can use a computer within the local network or over
the Internet.