Fujitsu BX960 S1 Server User Manual


 
BX960 S1 Operating Manual 43
Control and display elements
Global Error indicator (orange)
Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
Flashes orange if an error was detected that requires service
intervention.
Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator lights up in failure mode until the faults are cleared.
You can find more details on the indicated errors in the System
Event Log (SEL), in the Management Blade Web interface, on the
ServerView Local Service Panel, on the ServerView Local
Service Display, in the ServerView Operations Manager or via the
iRMC S2's Web interface.
CSS CSS indicator (yellow)
Lights up yellow if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of
precaution) with the CSS concept.
Flashes yellow if an error was detected that you can fix
yourself with the CSS concept.
Does not light up when the system is OK.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator lights up in failure mode until the faults are cleared.
For more information on the CSS concept, see "Customer Self
Service (CSS)" on page 11.
ID ID indicator (blue)
Lights up blue when the system has been selected by pressing the
ID button. To deactivate, press the button again.
The ID indicator can also be activated via the Management Blade
Web interface and via the ServerView Operations Manager and
the iRMC S2 Web interface and its status reported to the
ServerView Operations Manager and the iRMC S2.
!