Fujitsu M4000/M5000 Server User Manual


 
26 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 July 2007
6496337 Theʺcpumemdiagnosisʺmodulemayfailto
loadafteruncorrectableerror(UE)panic.
Systemswillfuncti on correctly but events
normallyautomaticallydiagnosedbyFMA
usingthismodulewillrequiremanual
diagnosis.
Example:
SUNW-MSG-ID: FMD-8000-2K, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Thu Feb 15 15:46:57 JST
2007
PLATFORM: SUNW,SPARC-Enterprise,
CSN: BE80601007, HOSTNAME: col2-ff-
em7-d0
Ifproblemoccu rred ,implementthefollowing
workaround:
1. Removethefol lo w in gfi le .
# rm /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
2. Restartfm d servi ce .
# svcadm restart fmd
Toavoidthispro bl emin
advance,
addʺrm‐f/var/fm/fmd/ ckp t /cpu me m
diagnosis/cpumemdiagnosisʺin
/lib/svc/ m et hod /sv c dumpadmfileasbelow.
#
# We haven't run savecore on a
dump device yet
#
savedev=none
rm -f /var/fm/fmd/ckpt/cpumem-
diagnosis/cpumem-diagnosis
#
6498283 UsingtheDRdeleteboardcommandwhile
psradmoperationsarerunningonadomain
mightcauseasystempanic.
Thereisnoworkaround.Ch e ck forthe
availabilityofapatchforth i sdefect.
6499304 CPUisnʹt
offlinedandunexpectedmessageis
displayedonconsolewhenmanycorrectable
error(CE)occurs.
Example:
SUNW-MSG-ID: FMD-8000-11, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Fri Feb 2 18:31:07 JST
2007
PLATFORM: SPARC-Enterprise, CSN:
BE80601035, HOSTNAME: FF2-35-0
CheckCPUstatusonXSCF.
TABLE 6 SpecificIssuesandWorkaroundsConcerningSolaris(Continued)
CR ID Description Workaround