30 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 July 2007
6536564 showlogs(8)andshowstatus(8) command
onXSCFmightreportwrongI/Ocomponent
duetowrongdiagnosisbySolarisFa ult
managementArchitecturewhenfaultsinI/O
devicesoccur.
Toavoidthispro blem, issuethefollowing
commandsonthedomain.
# cd /usr/platform/SUNW,SPARC-
Enterprise/lib/fm/topo/plugins
# mv ioboard.so ioboard.so.orig
# svcadm restart fmd
Ifthefollowingmessagesar edisplayedonth e
domain,contactasales
representativeora
certifiedserviceengineer.
Example:
SUNWMSGID:SUNO S 80001L,TYPE:
Defect,VER:1,SEVERITY:Minor
EVENTTIME:SunMay618:22:24PDT2 007
PLATFORM:SUNW,SPA RCEnterprise,CSN:
BE80601007,HOSTNAME: sparc
6537511 Bluetoothpartnerishungduringsecuritytests
execution
Restartappl icationserver
6539084 SunPCIeQuadportGigabitEthernetAdapter
UTPcard(X4447A
Z)mightpanicduringa
reboot.
Thereisnoworkaround.Ch e ck forthe
availabilityofapatchforth i sdefect.
6542632 MemoryleakinPCIemoduleifdriverattac h
fails.
Thereisnoworkaround.Ch e ck forthe
availabilityofapatchforth i sdefect.
6545685 Ifthefol lo w in gmessagedisplayedonth eOS
console,
memorydegradationorXSB
deconfigurationmayoccurinthesubsequent
reboot.
Example:
mcopl:WARNING:mcoplrewritetimeouton
/LSB0/B0
Addthefollowingto/etc/system andthen
rebootthedomain:
set mc-opl: mc_max_rewrite_loop =
10000
TABLE 6 SpecificIssuesandWorkaroundsConcerningSolaris(Continued)
CR ID Description Workaround