ErgoPro m664-series PC Specialist's Handbook
Page 3-2 Edition 1 - Release 1 - March 1998
Entering Resident Setup Utility (RSU)
!
Close all open files and leave your application program before entering Setup. You
cannot exit back into an application. The system automatically reboots when you leave
Setup.
To enter SETUP (i.e. RSU), do as follows:
1. Turn on the power to the system, or if the system is already on, shutdown properly the Operating
System and restart the system (f. eg. press CTRL+ALT+DEL).
2. To enter the Setup program (turn the computer on and) press <F2> when you see the message:
Press <F2> Key if you want to run SETUP
Moving around in RSU
Setup Key Description
<F1> or <Alt-H> Brings up a help screen for the current item.
<Esc> Exits the menu.
<←> or <→>
Selects a different menu screen.
<↑> or <↓>
Moves the cursor up or down.
<Home> or <End> Moves the cursor to the top or bottom of the window.
<PgUp> or <PgDn> Moves the cursor to the top or bottom of the window.
<F5> or <-> Selects the previous value for a field.
<F6> or <+> or <Space> Selects the next value for a field.
<F9> Loads the default configuration values for the current menu.
<F10> Saves the current values and exit Setup.
<Enter> Executes command or selects the submenu..
Setup Menu Screens
Setup Menu Screen Description
Maintenance Specifies the processor speed and clears the Setup passwords.
This is only available in configure mode. See section 2 for
information about configure mode
Main Allocates resources for hardware components
Advanced Specifies advanced features available through the chipset
Security Specifies passwords and security features
Power Specifies power management features
Boot Specifies boot options and power supply controls
Exit Saves or discards changes to the Setup program options