C141-E035-02EN 4 - 9
(4) Service clearance area
The service clearance area, or the sides which must allow access to the IDD for installation or
maintenance, is shown in Figures 4.9.
Figure 4.9 Service clearance area
(5) External magnetic field
The drive should not be installed near the ferromagnetic body like a speaker to avoid the
influence of the external magnetic field.
(6) Leak magnetic flux
The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak
magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux
does not affect to near equipment.
(7) Others
A hole or screw portion as shown in Figure 4.10 is used for adjusting air pressure balance
between inside and outside the DE. Do not fill with a seal or label.
Seals on the DE prevent the DE inside from the dust. Do not damage or peel off labels.
[Surface P’]
• Setting terminal
• External operator panel
connector
• Spindle sync connector
[Surface R]
• Hole for mounting screw
[Surface Q]
• Hole for mounting screw
[Surface P]
• Cable connection