C141-E035-02EN4 - 24
4.3.3 Cable connector requirements
Table 4.3 lists the recommended components cable connection.
Table 4.3 Recommended components for connection
Applicable
model
Name Par number Manufacturer Reference
(Figures 4.23
and 4.28)
MAx3xxxSP SCSI cable (CN1) Cable socket
(closed-end type)
786090-7 AMP S1
Signal cable — —
Power supply cable
(CN1)
Cable socket
housing
1-480424-0 AMP S2
Contact 60619-4
Cable 60617-4
External operator
panel (CN1)
Cable socket
housing
FCN-723J012/2M Fujitsu Limited S3
Contact FCN-723J-G/AM Fujitsu Limited
Cable AWG26 to 34
External operator
panel (CN7)
Cable socket
housing
FCN-723J016/2M Fujitsu Limited S4
Contact FCN-723J-G/AM Fujitsu Limited
Cable AWG28
MAx3xxxSC SCSI connector
(CN1)
Connector 787311-1 AMP
(1) SCSI cable
All SCSI devices on one bus are daisy-chained with an SCSI cable. A terminating resistor
must be mounted in the SCSI device at each end of the SCSI cable.
Because an SCSI terminating resistor module has been mounted in the IDD of single-ended
type SCSI at factory shipment, it must be set to not-connection when the IDD is not connected
at either end of the SCSI cable. See Section 5.3 for details.
The maximum number of SCSI devices that can be connected to the SCSI bus is 16 for the 16-
bit SCSI, including the host adapter, IDD, and other SCSI equipment.
For the 16-bit SCSI, the connector for the SCSI cable must be an unshielded 68-contact socket
having 34-contact rows spaced 1.27 mm (0.05 inch) apart. (See Figure 4.26.)