22
MB15C02
(Continued)
■ USAGE PRECAUTIONS
• This device should be transported and stored in anti-static containers.
• This is a static-sensitive device; take proper anti-ESD precautions. Ensure that personnel and equipment are
properly grounded. Cover workbenches with grounded conductive mats.
• Always turn the power supply off before inserting or removing the device from its socket.
• Protect leads with a conductive sheet when handling or transporting PC boards with devices.
■ ORDERING INFORMATION
Parts number Package Remarks
MB15C02PFV1
16-pin Plastic SSOP
(FPT-16P-M05)
MB15C02PFV2
20-pin Plastic SSOP
(FPT-20P-M03)
∆MKr A euts N/A
x : 1.99999978 ms
y : −680 Hz
286.0050
MHz
2.00
kHz/div
285.9950
MHz
0 s 8.0000000 ms
2.00 ms
PS
1 V
0 V
• LOCK Frequency: PS on to 286.0 MHz
(fr = 25 kHz)
•V
DD = 1.2 V, VP = 1.2 V, Ta = +25°C
PS ON → 286.0 MHz, within ± 1 kHz