Fujitsu MBA3073RC Computer Drive User Manual


 
5.1 Mode Parameters
5.1.13 Additional Error Recovery Parameters (Page Code = 21)
The page descriptor format of this MODE SELECT parameter is shown in Table
5.19.
Table 5.19 MODE SELECT parameters: additional error recovery parameters
[Fujitsu unique parameter]
Bit
Byte
7 6 5 4 3 2 1 0
0 0 0 1 0 0 0 0 1
1 X'02' (Page Length)
2 0 0 0 0 Number of retries during a Seek Error
Default 0 0 0 0 1 1 1 1
Variable 0 0 0 0 1 1 1 1
3 RFJ
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 0 0
a. Number of retries during a seek error
This parameter specifies the number of times repositioning is retried when a
seek error is detected. When zero is specified in this field, repositioning
retries are prohibited. The value specified in this field is applicable for all
commands which are accompanied by a seek operation.
b. RFJ (reserved by Fujitsu)
All the bits in byte 3 are reserved by Fujitsu. The user should specify "0" in
this bit.
C141-C013 325