18 Installation
There are three main indicator LEDs on the front of the XG2000: Power LED, Alarm LED, and
Status LED. The following explains the LED display under various conditions.
*1: If the XG2000 is operating normally.
If a problem occurs, the front panel LEDs and the LEDs on the individual parts can be used to
identify the trouble:
*2: Only detectable and indicated when two power supply units are installed and connected to separate,
independent power supplies.
*3: Condition of the Alarm LED will depend on the state of the system.
*4: Condition of the Status LED will depend on the state of the system.
Note that the XG2000 will shut itself off when the Temperature error is detected.
Any problems other than those that occur during start up are recorded in the event log. For
details of the event log, refer to the "XG2000 User’s Guide".
Display LEDs
XG2000 Condition
LED
Power Alarm Status
Off Off Off Off
Starting up Power just turned on On Off Off
System starting up On Off *1 Blinking
System start-up completed On Off *1 On
Operable On Off *1 On
After shutdown Off On Off
XG2000 Condition
LED
Power Alarm Status LED on failed part
Problem
detected
Startup error On ---*3 Blinking ---
Rear fan error On On ---*4 Rear Fan LED: Orange
Power fan error On On ---*4 Power Supply LED: Orange
No AC supply *2 On On ---*4 Power Supply LED: Orange
Power supply error On On ---*4 Power Supply LED: Orange
Voltage error On On ---*4 ---
Temperature error On On ---*4 ---
System dump in
progress
On On ---*4 ---