SB-1000 MANUAL
SPECIFICATIONS
Input:
Capacity: 1000VA / 600W
Voltage: +/-25% at line input
Frequency: 50 or 60 Hz +/-10% (auto sensing)
Output:
Voltage (on battery): Simulated sine wave at 110V/115V/120V or
220V/230V/240V +/- 5%
Frequency (on battery): 50 or 60 Hz +/- 5%
AC Line Voltage Regulation:
Input Voltage Range: 90 VAC to 150 VAC
(E-Version Input Voltage Range: 175 VAC to 290 VAC)
Output Voltage Range: 109 VAC to 131 VAC
(E-Version Output Voltage Range: 201 VAC to 252 VAC)
Transfer Time: 2-4 milliseconds, including detection time
Protection and Filtering:
EMI/RFI filter: 10 dB at 0.15 MHz, 50dB at 30MHz
Overload Protection: UPS automatic shutdown if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
Unit Input: Circuit breaker for overload & short circuit protection
10Base-T Cable Port: Phone/Fax (UTP, RJ-45) compatible jacks
Short Circuit: UPS output cut off immediately or input fuse protection
Batteries:
Type: Sealed, maintenence-free lead acid
Typical Recharge Time: 8 hours to 90% full capacity
Protection: Automatic self test & discharge protection, Replace battery indicator
Back-up Time: 3 - 180 min. (depending on computer load)
Physical:
Net Weight: 26 lbs
Shipping Weight: 29 lbs
Dimension: 14.8” W (19” with rack ears) x 13.8” D x 1.75” H
Alarm:
Battery Back-up: Slow beeping sound (about 0.47 Hz)
Battery Low: Rapid beeping sound (about 1.824 Hz)
Overload: Continuous beeping sound
Interface:
RS-232C port interface: RS-232C Bi-directional communication port
Environment:
Ambient Operation: 3,500 meters max. elevation, 0-95%
humidity non-condensing, 0-40 deg C
Audible Noise: <40dBA (1 meter from surface)
Storage Condition: 15,000 meter max.