Furuno VR-3000S Switch User Manual


 
FURUNO
VR-3000
SP - 1 E4437S01C
070810
SPECIFICATIONS OF VOYAGE DATA RECORDER
VR-3000
The Voyage Data Recorder (VDR) is a recording system required on certain categories of ships
from 1st July 2002 by the revised SOLAS Chapter V. VR-3000 fully complies with the IMO
Resolution A. 861 (20) and IEC 61996 testing standard.
1 GENERAL
1.1 Recording period DRU: 12 hours, Backup HDD: 12 hours x 4 recording areas
1.2 Battery backup More than two hours after loss of ship’s mains
2 DATA COLLECTING UNIT (DCU)
2.1 CPU Intel Pentium M 1.6GHz
2.2 Memory 512 M byte
2.3 Input signal Bridge audio: 6ch (775mV AC/600 ohm)
VHF audio: 2ch (775mV AC/600 ohm)
Serial (IEC61162-2): 4ch
Serial (IEC61162-1): 12ch
Radar Image: 1ch standard (4ch max, w/ option)
Analog signal: 16ch standard (48ch max, w/ option)
(-10 to +10V, 0 to +10V, 4 to 20mA)
Digital signal: 64ch standard (194ch max, w/ option)
Remote ACK input: 1ch
2.4 Output signal Ethernet 100base-TX: 2ch
System fail signal: 1ch
Local ACK signal 1ch
IEEE1394a 1ch (for data extraction)
3 DATA RECORDING UNIT (DRU)
3.1 Chassis Protective capsule
3.2 Memory capacity 6 GB or 9 GB
3.3 Shock resistance 50G x 11 ms
3.4 Penetration resistance 100mm diameter pin with 250 kg weight, dropped from 3 m height
3.5 Fire resistant 1100°C for 1 hour, 260°C for 10 hours
3.6 Submersible 6000 m (60MPa)
3.7 Acoustic beacon Replaced every 6 years, maximum depth 6000m, 30 days 37.5kHz
10ms pulse transmission
4 MICROPHONE
4.1 AGC amplifier output 775mV AC/600 ohm