Magnum 1000 Workgroup Hubs Installation and User Guide (04/02)
8
www GarrettCom com
..
2.3 Internal Connections, basic AUI Port and Port Modules
Figure 2.3a shows the internal layout of the Magnum 1008 for each of the two
rear port configuration options (see section 2.2.1). Unless otherwise specified at the
time of order, the Magnum 1008 is shipped with a basic AUI port. For greater
application flexibility, any of the Magnum PMs may be specified at the time of order for
factory configuration. It is also possible for the rear port to be re-configured in the field
by a trained technician to exchange or add Port Modules.
NOTE: When changing from the basic AUI port to a Port Module option in the field, it
is necessary to have a Port Module connector cable (part number CBL-PM available as a
spare part from GCI) in addition to the desired PM.
Figure 2.3a: Model 1008 Internal Connections, Basic AUI port and Port Module
Figure 2.3b shows the internal layout of the Magnum 1016 and 1024
Workgroup Hubs. (The Model 1024 is shown in the figure, but all rear port connections
are identical for the Model 1016). One rear port always has the basic AUI port in it.
The bonus port slot, in the center of the chassis rear, is available for configuring any
PM. For application flexibility, any of the Magnum PMs may be specified on an order
for factory configuration in the bonus port slot. It is also possible for the bonus port to
be re-configured in the field by a trained technician to exchange or add Port Modules.
NOTE: When adding a Port Module option to the Bonus Port slot in the field, it is
necessary to have a Port Module connector cable (part # CBL-PM available as a spare
part from GCI) in addition to the desired PM. See also Section 2.4.12, Special Option.
Optional PM card
(BPM shown)
Basic AUI port
PM Ribbon cable with 16 pin headers.
(Included only when PM is factory installed.
May be ordered separately as part # CBL-PM)
NOTE:
Use P1 for Basic AUI port
Use P1-RPM for PM
P1
P1-RPM P1
P1-RPM