Chapter 2: Unit Installation
Mounting
The included hardware allows the Gateway Series appliance to be wall
mounted, rack mounted side-by-side with another Gateway Series
appliance, or placed flat on a level surface. If a single Gateway Series
appliance is to be rack mounted, the optional long mounting bracket (not
supplied, part number 3244-00042) must be used. The optional long
mounting bracket can be ordered by contacting a Digium reseller or
Digium directly.
Important
Reliable earth grounding of rack-mount equipment should be
maintained. Particular attention should be given to provide
connection other than direct connections to the branch circuit
(e.g., use of power strips).
Important
Mounting of the Gateway Series appliance in a rack should be
such that no hazardous condition is achieved due to uneven
mechanical loading. Do not place heavy objects on top of the
unit, or pull down on the mounted unit. Consider the
mechanical loading of external cables. The weight of the cables
can pull on the unit and create uneven loading. Secure heavy
cables with external cable trays.
Important
If rack mounting, install the Gateway Series appliance in a rack
so that the amount of airflow required for safe operation is not
compromised.