Gefen GTB-MHDMI1.3-441 Switch User Manual


 
13
54321
9876
12345
6789
Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface
This feature allows for easy integration into automated systems capable of
transmitting RS-232 commands. Please use the settings listed below to
con gure the RS-232 port of the user’s system.
Transmitting the appropriate numeric ASCII character will simulate key presses
on the RMT-4IR remote control.
Binary Table
ASCII RMT-4IR
Button
Binary
1 1 0011 0001
2 2 0011 0010
3 3 0011 0011
4 4 0011 0100
RS-232 Settings
Bits per second ................................................................................................. 19200
Data bits .................................................................................................................... 8
Parity .................................................................................................................. None
Stop bits .....................................................................................................................1
Flow Control ....................................................................................................... None
RS-232 SERIAL CONTROL