Graco GE-DS-242-POE Network Card User Manual


 
Chapter 4: Web-Based Management
80 GE-DS-242-PoE Managed Ethernet Switch User Manual
NOTE: Path cost "0" is used to indicate auto-configuration mode. When the short path
cost method is selected and the default path cost recommended by the IEEE 8021w
standard exceeds 65,535, the default is set to 65,535.
By default, the system automatically detects the speed and duplex mode used on
each port, and configures the path cost according to the values shown below.
Table 4-1: Recommended STP Path Cost Range
Port Type IEEE 802.1D-1998 IEEE 802.1w-2001
Ethernet 50-600 200,000-20,000,000
Fast Ethernet 10-60 20,000-2,000,000
Gigabit Ethernet 3-10 2,000-200,000
Table 4-2: Recommended STP Path Cost Range
Port Type Link Type IEEE 802.1D-1998 IEEE 802.1w-2001
Ethernet Half Duplex
Full Duplex
Trunk
100
95
90
2,000,000
1,999,999
1,000,000
Fast Ethernet Half Duplex
Full Duplex
Trunk
19
18
15
200,000
100,000
50,000
Gigabit Ethernet Full Duplex
Trunk
4
3
10,000
5,000