Hand Held Products 5620 Scanner User Manual


 
6 - 4 IMAGETEAM™ 2020/5620 System Manual
When Check Character is set to
Validate, but Don’t Transmit
, the unit will only
read Codabar bar codes printed
with
a check character, but will not transmit the
check character with the scanned data.
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the
scanner looks for a Codabar symbol having a “D” start character, adjacent to a
symbol having a “D” stop character. In this case the two messages are
concatenated into one with the “D” characters omitted.
Default = On.
Select Require to prevent the scanner from decoding a single “D” Codabar
symbol without its companion. This selection has no effect on Codabar symbols
without Stop/Start D characters.
* No Check Character
Validate Modulo 16 and Transmit
Validate Modulo 16, but
Don’t Transmit
A12D D34A
Codabar
Character
Stop Start StopStart
On
* Off
Require