C-2
www.hp.com
Hardware Reference Guide
Electrostatic Discharge
Grounding Methods
There are several methods for grounding. Use one or more of
the following methods when handling or installing
electrostatic-sensitive parts:
■
Use a wrist strap connected by a ground cord to a grounded
Thin Client chassis. Wrist straps are flexible straps with a
minimum of 1 megohm +/- 10 percent resistance in the ground
cords. To provide proper grounding, wear the strap snug against
the skin.
■
Use heelstraps, toestraps, or bootstraps at standing workstations.
Wear the straps on both feet when standing on conductive floors
or dissipating floor mats.
■
Use conductive field service tools.
■
Use a portable field service kit with a folding static-dissipating
work mat.
If you do not have any of the suggested equipment for proper
grounding, contact an HP authorized dealer, reseller, or service
provider.
✎
For more information on static electricity, contact an HP authorized
dealer, reseller, or service provider.