HP (Hewlett-Packard) A7340-96002 Switch User Manual


 
18 Quick Start Guide
Workstation that has a terminal emulator application (such as
HyperTerminal)
Serial cable provided with the switch, for connecting the switch to the
workstation
An unused IP address
Ethernet cable for connecting the switch to the workstation or to a
network containing the workstation
SFPs and FC cables, as required to connect the switch to the fabric
To configure the FC 16B and connect it to a fabric:
1. Replace the factory IP address and related information with the IP
information provided by your network administrator by completing the
following steps:
a. Remove the shipping plug from the serial port and insert the serial
cable provided with the FC 16B.
b. Connect the other end of the serial cable to an RS-232 serial port on
the workstation. If no RS-232 serial port is available on the
workstation, the adapter on the end of the serial cable can be removed
to use the RJ-45 connector to create a serial connection.
c. Verify that the switch power is on and POST is completed.
d. Disable any serial communication programs running on the
workstation.
e. Open a terminal emulator application (such as HyperTerminal on a
PC, or TERM in a UNIX environment), and configure as follows:
In a Windows 95, 98, 2000, or NT environment:
Parameter Value
Bits per second: 9600
Databits: 8
Parity: None
Stop bits: 1
Flow control: None