HP (Hewlett-Packard) BL30p Network Card User Manual


 
NOTE:
NOTE: NOTE:
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Operating andOperating and
Operating and
Performance
PerformancePerformance
Performance
Specifications for ProLiant
Specifications for ProLiantSpecifications for ProLiant
Specifications for ProLiant
BL p-Class RJ-45 Patch
BL p-Class RJ-45 PatchBL p-Class RJ-45 Patch
BL p-Class RJ-45 Patch
Panel
PanelPanel
Panel
Dimensions
DimensionsDimensions
Dimensions
Height
10.405 in (26.43 cm)
Width
1.535 in (3.899 cm)
Depth
27.697 in (70.35 cm)
Capability
CapabilityCapability
Capability
IEEE 802.2, 802.3, 802.3u
Network Transfer Rate
Network Transfer RateNetwork Transfer Rate
Network Transfer Rate
10 Base-T (half-duplex)
10 Mbps
10 Base-T (full-duplex)
20 Mbps
100 Base-TX (half-duplex)
100 Mbps
100 Base-TX (full-duplex)
200 Mbps
1000 Base-TX (full-duplex)
1000 Mbps
Connector
ConnectorConnector
Connector
Network
16 RJ-45 in the back
Cable Support
Cable SupportCable Support
Cable Support
10 Base-TX
Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)
100 Base-TX
Category 5 UTP (2 pair); up to 328 ft (100 m)
1000 Base-TX
Category 5E (4 pair); up to 328 ft (100 m)
Power Requirements
Power RequirementsPower Requirements
Power Requirements
200 mA at + 5V DC; 500 mA at -48V
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
(non-condensing)(non-condensing)
(non-condensing)
Operating
20% to 80%
Non-operating
5% to 95%
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
Wet Bulb Temperature
Operating
82.4° F (28° C)
Non-operating
101.7° F (38.7° C)
NOTE:
NOTE: NOTE:
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Operating andOperating and
Operating and
Performance
PerformancePerformance
Performance
Specifications for ProLiant
Specifications for ProLiantSpecifications for ProLiant
Specifications for ProLiant
BL p-Class GbE
BL p-Class GbEBL p-Class GbE
BL p-Class GbE
Interconnect Switch
Interconnect SwitchInterconnect Switch
Interconnect Switch
Dimensions
DimensionsDimensions
Dimensions
Height
10.405 in (26.43 cm)
Width
1.535 in (3.899 cm)
Depth
27.697 in (70.35 cm)
Weight
WeightWeight
Weight
11.5 lb/5.2 kg per interconnect switch
Performance
PerformancePerformance
Performance
9.6 Gbps external port bandwidth per server blade enclosure (full duplex)
Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per
gigabit port, (64-byte packets)
Non-blocking, full-wire speed for all connections
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Forwarding Mode
Forwarding ModeForwarding Mode
Forwarding Mode
Store and forward
MAC Addresses
MAC AddressesMAC Addresses
MAC Addresses
8,191 per interconnect switch; MAC address based filtering and MAC
address packet priority configuring
QuickSpecs
HP ProLiant BL30p Server Blade
HP ProLiant BL30p Server BladeHP ProLiant BL30p Server Blade
HP ProLiant BL30p Server Blade
Technical Specifications
DA - 11958 Worldwide — Version 19 — August 15, 2005
Page 40