HP (Hewlett-Packard) BL30p Network Card User Manual


 
Forwarding Table
Forwarding TableForwarding Table
Forwarding Table
Age Time
Age TimeAge Time
Age Time
Maximum age: 1 to 1,000,000 seconds; default: 300 seconds
Memory
MemoryMemory
Memory
32MB Main, 6MB flash and 16MB packet buffer per interconnect switch
Compliance
ComplianceCompliance
Compliance
IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D,
802.1p, 802.3ac, 802.3ad (Static), and 802.1Q
SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC
2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674),
Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap
(RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch
MIBs and Environmental Traps
IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC
854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC
2131) and ZModem,
Network Transfer
Network TransferNetwork Transfer
Network Transfer
Rate
RateRate
Rate
10 Base-T (half-duplex)
10 Mbps
10 Base-T (full-duplex)
20 Mbps
100 Base-TX (half-duplex)
100 Mbps
100 Base-TX (full-duplex)
200 Mbps
1000 Base-TX (half and
full-duplex)
2000 Mbps
1000 Base-SX (full-duplex)
2000 Mbps
Connector
ConnectorConnector
Connector
12 RJ-45, 2 DB-9 (C-GbE Interconnect Kit)
4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit)
EMI
EMIEMI
EMI
FCC Class A
ICES-003 Class A
AS/NZS 3548 Class A
VCCI Class A
Safety
SafetySafety
Safety
UL/CUL Listed Accessory
CE
Power
PowerPower
Power
Requirements
RequirementsRequirements
Requirements
-48VDC: 1050 mA, 50 W maximum (per interconnect switch)
Temperature
TemperatureTemperature
Temperature
R range
R rangeR range
R range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
(non-condensing)(non-condensing)
(non-condensing)
Operating
20% to 80%
Non-operating
5% to 95%
Wet Bulb
Wet BulbWet Bulb
Wet Bulb
Temperature
TemperatureTemperature
Temperature
Operating
82.4° F (28° C)
Non-operating
101.7° F (38.7° C)
NOTE:
NOTE: NOTE:
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating and
Operating andOperating and
Operating and
Performance
PerformancePerformance
Performance
Specifications for ProLiant
Specifications for ProLiantSpecifications for ProLiant
Specifications for ProLiant
BL p-Class GbE2
BL p-Class GbE2BL p-Class GbE2
BL p-Class GbE2
Dimensions
DimensionsDimensions
Dimensions
Height
10.405 in (26.43 cm)
Width
1.535 in (3.899 cm)
Depth
27.697 in (70.35 cm)
QuickSpecs
HP ProLiant BL30p Server Blade
HP ProLiant BL30p Server BladeHP ProLiant BL30p Server Blade
HP ProLiant BL30p Server Blade
Technical Specifications
DA - 11958 Worldwide — Version 19 — August 15, 2005