HP (Hewlett-Packard) DL380 G7 Server User Manual


 
Hardware options installation 65
8. Install the hard drives ("Hot-plug SAS hard drive options" on page 54).
9. Install the hard drive blanks.
10. Remove the full-length expansion board retainer (on page 28) if any full-length expansion boards are
installed.
11. Remove the PCI riser cage (on page 29).
12. Install the optional SAS controller. For installation instructions, see the documentation that ships with the
SAS controller option.
13. Remove the air baffle (on page 31).
14. Connect one end of the power cable to the SAS backplane and the other end to the system board.
15. Install the air baffle.
16. Install the PCI riser cage.
17. Install the full-length expansion board retainer (on page 30) if any full-length expansion boards are
installed.
18. Install the primary hard drive cage.
19. Connect one end of each SAS cable to the SAS controller. For connector information, see the
documentation that ships with the SAS controller option.
20. Install the access panel (on page 26).
21. Install the server into the rack ("Installing the server into the rack" on page 35).
22. Power up the server (on page 24).
HP Trusted Platform Module option
Use these instructions to install and enable a TPM on a supported server. This procedure includes three
sections:
1. Installing the Trusted Platform Module board.
2. Retaining the recovery key/password (on page 68).