HP (Hewlett-Packard) ML370 Server User Manual


 
Component identification 82
HP Systems Insight
Display LED color
Internal system
health LED color
Status
PPM failure, slot X
(amber)
Red One or more of the following conditions may exist:
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
DIMM failure, slot X
(amber)
Red One or more of the following conditions may exist:
DIMM in slot X has failed.
DIMM has experienced a multi-bit error.
Amber One or more of the following conditions may exist:
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
DIMM bank error (all
slots in one bank,
amber)
Red One or more of the following conditions may exist:
The bank is not populated entirely.
All DIMMs in the bank do not match.
Memory riser board is missing or not fully seated.
DIMM failure (all
slots, amber)
Red One or more of the following conditions may exist:
No valid or usable memory is installed in the system.
The banks are not populated in the correct order.
Overtemperature alert
(amber)
Red
System temperature has exceeded OS cautionary level or
critical hardware level.
Fan (amber) Red A required fan has failed.
Amber A redundant fan has failed.
SAS and SATA device numbers
The server supports a combination of up to 16 SAS and SATA hard drives in two hard drive cages.
HP recommends populating hard drive bays starting with the lowest SAS or SATA device number.