CNT DOTS: Displays the number of dots in a message and the volume of ink needed for each
printing.
SEL NOZZL: This setting controls what channels are used to print.
o AUTO: (Recommended) the QM2 selects the best nozzle configuration based on
operating conditions. (300 DPI)
o EVEN: Prints using the even channels. (300 DPI)
o ODD: Prints using the odd channels. (300 DPI)
o BOTH: Prints using both channels. (600 DPI)
RS485: This submenu configures the QM2 communications. Parameters in this menu should
only be adjusted under the advice of MSSC, LLC.
DRV PULSE: This menu controls the print head operating parameters.
SENSR DELAY: This setting allows for an overall offset for printing. This setting offsets all
messages in addition to the DELAY setting in the Parameter menu.
GAP 2L: This setting changes the gap between lines on the special message function. The
value can be set from 0 to 90%. This is how the print height 6mm-1mm is achieved. See page 13
for description of .
2
S
2
S
Serial Numbers/Consecutive Numbering
The serial number setup menu can be accessed from the main screen by pressing the S/N key. This
menu allows for the adjustment of how serial numbers are printed.
NEXT S/N: Sets the next serial number to be printed. To change, enter the new number using
the keypad.
RESET: Resets the NEXT S/N value to the value in INITIAL. To use, press or key to
select yes and press .
LENGTH: Sets the desired number of digits in the serial number. The maximum number of
digits is 8.
INCREMENT: Sets the amount the serial number increases by at each sequential change.
INITIAL: sets the value that NEXT S/N is set to when RESET is used.
COUNT UP: Sets the number of times a serial number is printed before advancing to the next
number.
COUNTING: Keeps track of how many times a repeated serial number has been printed. This
value can be set to reflect the number actually printed.
NOTE: COUNTING is decreased by 1 when the serial number setup menu is accessed.