HP (Hewlett-Packard) Series 8212zl Switch User Manual


 
1-7
Introducing the ProCurve Series 8200zl Switch
Front of the Switch
Introducing the ProCurve
Series 8200zl Switch
PoE
(green/orange)
On green
Off
If any PoE modules are installed.
If no PoE modules are installed.
Blinking
orange
1
Blinking
orange
2
Internal PoE fault.
External load fault or denied PoE power.
Tmp
(green/orange)
Off Switch temperature is normal.
Blinking
1
An over temperature condition has been detected.
Fan
(green/orange)
On green The cooling fans are operating normally.
Blinking
orange
1
One or more of the cooling fans have failed. The switch Fault LED will be blinking
simultaneously.
Internal Power 1-4
(green/orange -
numbers
corresponding to
the power supply
positions)
On green A power supply is installed in the position in the back of the switch corresponding
to the number, and the supply is plugged in to an active AC power source. As
shipped, the switch has a single power supply in position 1.
Off A power supply is not installed in the position corresponding to the number.
Blinking
orange
1
The power supply installed in the position corresponding to the number is not
plugged in to an active AC power source, or has experienced a fault. The switch
Fault LED will be blinking simultaneously.
EPS (1 and 2)
(green/orange)
On green
Off
An External Power Supply is connected.
No External Power Supply is connected.
Blinking
orange
1
The External Power Supply has a fault, or is connected but not plugged into AC
power.
Fabric Modules
(1 and 2)
(green/orange)
On green
Off
A Fabric Module is installed and functioning correctly.
A Fabric Module is not installed or has failed.
Blinking
orange
1
The Fabric Module has a fault.
The switch Fault LED will be blinking simultaneously.