Hitachi SJ-FB Power Supply User Manual


 
31
Chapter 7 FUNCTIONS
A044: 1
st
Control Method
P052: 1
st
Proportional gain
7.4 Speed control (P/PI) switching function
Relation
Speed control mode is normally controlled by
proportional-integration compensation (Pi), which keeps the
deviation between the actual speed and speed command
becomes 0. Further, you can also achieve a propotional control
function, which can be used as drooping operation (i.e. one load
with several inverters) with this option card.
Set P/PI switching function to one of the intelligent input terminal 18 by the operator to achieve
this function. (Input ‘43’ in one of C001C008.) When this is turned on, control mode becomes
proportion control (P).
Please set proportional gain(Kpp ; a value used to decide the speed change rate) to H052 by a
digital operator. The relationship between the Kpp value and the speed change rate is shown
below.
(%)
)ValueSetKpp(
10
=)RateChangeSpeed(
Relationship between Kpp Value and Speed Change Rate
0 Rotation Speed
Torque
100 %
PI controlP control
(A)
Figure 7-6 Torque characteristic (P/PI)
()
frequencybasespeedsSynchronou
ATorqueRatedatErrorSpeed
=)RateChangeSpeed(
Relationship between Speed Change Rate and Rated Rotation Speed