X200 Inverter Specifications
Model-specific tables for 200V and 400V class inverters
The following tables are specific to X200 inverters for the 200V and 400V class model
groups. Note that “General Specifications” on page 1
-10 apply to both voltage class
groups. Footnotes for all specification tables follow the table below.
Item 200V class Specifications
EU version 002SFEF 004SFEF 005SFEF 007SFEF 011SFEFX200 inverters,
200V models
USA version 002NFU 004NFU 007NFU
kW 0.2 0.4 0.55 0.75 0.11Applicable motor size *2
H
P 1/4 1/2 3/4 1 1.5
230V 0.5 1.0 1.1 1.5 1.9Rated capacity
(kVA)
240V 0.5 1.0 1.2 1.6 2.0
Rated input voltage - SFEF type: 1-phase input only
- NFU type: 1-phase or 3-phase input
1-phase: 200V-15% to 240V +10%, 50/60Hz r5%
3-phase: 200V-15% to 240V r10%, 50/60Hz r5%
EU version SFEF series : EN61800-3 category C1 filterIntegrated EMC
filter
USA version
EU version 3.1 5.8 6.7 9.0 11.2Rated input
current (A)
USA version 1.8 3.4 - 5.2 -
Rated output voltage *3 3-phase: 200 to 240V (proportional to input voltage)
Rated output current (A) 1.4 2.6 3.0 4.0 5.0
Efficiency at 100% rated output 89.0% 92.3% 93.2% 94.1% 94.7%
at 70% output 18 24 26 33 42
Watt loss (fc=3kHz)
Approximate (W)
at 100% output 22 31 34 44 58
Starting torque *7 100% at 6Hz
100%: d50Hz
50%:
d60Hz
Dynamic braking,
approx. % torque
(short time stop
from 50/60Hz) *8
Capacitive feedback type, dynamic braking unit and
braking resistor optional, individually installed
Braking
DC braking Variable operating frequency, time, and braking force
Kg 0.8 1.0 1.5 1.5 2.4EU version
(-SFEF)
lb 1.77 2.21 3.31 3.31 5.30
Kg 0.8 0.9 1.5
Weight
USA version
(-NFU)
lb 1.77 1.99 3.31
15
Getting started
1 5
Getting started