3 - 20
Sequence Match Beeper
By default, the scanner beeps when a sequence match is found. If you
want the scanner to remain silent, scan the Sequence Match Beeper Off
bar code below.
Default = Sequence Match Beeper On.
Partial Sequence
If an output sequence operation is terminated before all your output
sequence criteria are met, the bar code data acquired to that point is a
“partial sequence.”
Scan Discard Partial Sequence to discard partial sequences when the
output sequence operation is terminated before completion.
Scan Transmit Partial Sequence to transmit partial sequences. (Any
fields in the sequence where no data match occurred will be skipped in the
output.)
If you have programmed a Sequence Timeout (page 3-19) and
the timeout is reached, the partial sequence is transmitted.
Default = Dis-
card Partial Sequence.
Require Output Sequence
When an output sequence is Required, all output data must conform to an
edited sequence or the scanner will not transmit the output data to the host
device. When it’s On/Not Required, the scanner will attempt to get the
output data to conform to an edited sequence but, if it cannot, the scanner
transmits all output data to the host device as is.
Sequence Match Beeper Off
* Sequence Match Beeper On
Transmit Partial Sequence
* Discard Partial Sequence