Honeywell 1200G Scanner User Manual


 
5 - 4
Data Format Editor Commands
Send Commands
Send all characters
F1 Include in the output message all of the characters from the input
message, starting from current cursor position, followed by an insert
character.
Syntax = F1xx
where xx stands for the insert character’s hex
value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Send a number of characters
F2 Include in the output message a number of characters followed by an
insert character. Start from the current cursor position and continue for
“nn” characters or through the last character in the input message,
followed by character “xx.”
Syntax = F2nnxx
where nn stands for the
numeric value (00-99) for the number of characters, and xx stands for
the insert character’s hex value for its ASCII code.
Refer to the ASCII Conversion Chart (Code Page 1252) on page A-4
for decimal, hex and character codes.
Terminal ID Table
Terminal Model(s)
Terminal
ID
IBM PC/AT and compatibles
003
PS2 Keyboard
002
USB SurePOS Handheld
Scanner
128
USB SurePOS Tabletop
Scanner
129
RS232 True
000
TTL
000
RS485
051
USB Serial
130
PC Keyboard
124
Mac Keyboard
125
Japanese Keyboard (PC)
134
HID POS
131