Honeywell 3820 Barcode Reader User Manual


 
1 - 23
Each bar code above also programs the following suffixes for each symbology:
* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-
1, and IBM 4683 Port 17 Interfaces
**Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface
Connecting the Base with USB
A base can be connected to the USB port of a computer.
1. Connect the appropriate interface cable to the base and to the computer.
Make sure the cables are secured in the wireways in the bottom of the base
and that the base sits flat on a horizontal surface.
2. Program the base for the USB interface by scanning the appropriate
programming bar code.
3. Verify the base operation by scanning a bar code from the Sample Symbols
in the back of this manual.
Symbology
Suffix
EAN 8 0C
EAN 13 16
UPC A 0D
UPC E 0A
Code 39 00 0A 0B
Interleaved 2 of 5 00 0D 0B
Code 128 * 00 0A 0B
Code 128 ** 00 18 0B